Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Brushless excitation of synchronous generators and motors

Answer Posted / ramu

This is done with a rotating bridge bridge and a pilot
exciter

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1.main parts of generator? what is used A-check,B-check,C- check? 2.what is FM200 system in data centers? 3.difference between pac,ahu?

2125


What is the method to solve circuit using source transformation?

1139


why EMF IS INDUCED IN A CONDUCTOR WHEN FLUX LINKING WITH IT CHANGES ACCORDING TO FARADAYS LAW.

2018


How much minimum insulation required between 11kv/3.3kv transformer windings?

2426


What is the method for testing the differential protection stabilty in generator? When the time of starting What will happen if differentail protection connection wrong means?

2277


How to prepare electrical preventive maintenance plan & shedule of machine tools in manufacturing unit.

2160


Incoming line 11kv And transformer capacity is 2500kva. Consumption load is 1300A. Then fuse capacity is 11kv line.

1668


Draw a block diagramof Three UPS systems connected in Parallel mode?

2149


How to do fabrication , busbar and wiring cost for : 1. LT Panels 2. C& R Panel

1913


what happened when we supply a dc current in dc motor?? can it worked properly?

1944


What is difference between Over Current & Earth Fault protection?

2435


what is PDU in transformer?? which company manufacture??

1892


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1937


What is the formula formula for Busbar sizing and what are the things to be consider for Busbar Calculation?

2542


How the over load setting for HT Motors calculated-provided in Numerical Relay