Answer Posted / anand
both the limbs of the coil.
| Is This Answer Correct ? | 0 Yes | 6 No |
Post New Answer View All Answers
what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?
how to calculate the magnetizing current of ct ( 800A/1A) for Relay 64
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
How to test REF relay testing for LV panel as per Kahramaa standard?
what is the working process of over & under voltage relay.
132/66kv sub-station procation ?
How i can calculate current of cable according to ares?
advantage and disadvantage of team work?
why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?
sir my exam is on 19/6/2013 under electrical branch pls send me sample aptitude questions as well as sample technical questions for jindal steel and power company
what the Microsoft .NET framework is?
what is the difference between interconnection and intraconnections in the circuit diagrams
what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
What is a differential amplifier? Also, explain cmrr.