What are the complete specifications of a motor?.
Answer Posted / abc
Motor phase, type of motor,voltage rating, type of
connection (star/delta), Maximum current, operating
frequence, tolerance level, class of insulation, serial no,
design code, thermal resistivity, operating temperature,
class of frame, rated KW,power factor
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC
How will be the single line diagram of series trip HT breaker? how it works?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What happens if the series current double?
What are conduct on the testing in cf in ur site?
How work of capacitor in dc supply...???
Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?
How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?
which protection function should measure RMS value of current&DFT value of current?
magnetizer priciple
During regenerative breaking= A rotating magnetic field is reversed B slip is positive C torque is positive D slip is negative
What is the power factor of a transformer at no load?
What is the rate of WCT on the Electrical Contracts comprising of DG Sets and Civil Works in Delhi ?
how can found motors folt current ? how can disided circuit breakers caoicity and breaking capicity ?
what purpose to use excaiter in DG.?