Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

difference between HPLC & LC-MS

Answer Posted / spencer

With HPLC, components of a solution are separated, and elute
from the column at varying times. One can use the retention
time to estimate what the components are, but can not say
definitively.

With an LC-MS, in addition to components being separated,
the components are then fragmented and the identity of each
component be determined based on the distribution of the
fragments' mass to charge ratios.

In short, LC-MS is qualitative and the HPLC is not.

Is This Answer Correct ?    25 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to establish relative response factor for hplc. Why it is required?

1231


In IR spectra, generally a molecule vibrates without apply emr or ir light?

1982


Explain the relations between number of carbon atoms in alkanes and retention time ?

2150


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

927


before starting analytical method valodation what you checking? and how giving preference to start validation?

810


What should be the level/ Percentage of Arsenic in Arsenic free zinc.

2233


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

830


i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me

2737


using gradient pressure in gas chromatography are not ?using gradient pressure why

3391


How to calibration of the uv spectroscopy and its test?

1197


HI,I CLEARED BOB CLERK EXAM. MY INTERVIEW WILL BE ON 9TH OCTOBER,2010.PLEASE SEND ME INTERVIEW QUESTIONS AND ANSWERS. THANK YOU.

2251


What is diffrence between extractable volume and deliverable volume? Answer pls

4577


How do we get end points and how many end points are possible for citric acid and di-acid not theorotically answer should be given practically.

2584


In rs method development when we are going area normalization method to dilute standard method?

1528


Which is the highly polar and highly non polar column in HPLC?

2309