Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what do you mean by smart instruments?explain with example

Answer Posted / ashish gupta

Smart Instruments consists a microprocessor and they can be
calibrate at site and shows the value on the display. For
eg. Radar Level Transmitter are smart instruments because
they can be calibrated where they are installed by HART.
just enter the range & for what purpose you are using for
the instrument will show the level instantly.

Is This Answer Correct ?    12 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is temperature compensation?

5522


Explain bernoulli’s theorem.

1108


Make Heater Process Logic.

2148


Explain about the leakage class of the control valves

2034


i am from instrument branch i want paper patern of mahagenco . any pevious years paper regarding my branch send me please . please.....

2138


use of split range ? where it is used ? in which control loop it is used ?

2008


How to fix back the valve actuator stem

2111


What materials are used in thermo wells?

1226


what is the usage of QDV & VOLUME BOOSTER

2387


I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1945


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

2251


what is maxdna ?. explain about the software details.

4423


Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure

2028


can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).

2069


line up procedure for dp type flow transmitter?

1948