Answer Posted / sumanth kumar b
LETS CONSIDER VOLTAGE AS A REFERENCE THEN IF THE LOAD IS INDUCTIVE THEN THE CURRENT LAGS BY 90 DEGREES WITH RESPECT TO VOLTAGE.THE INDUCTIVE REACTANCE XL=J2*PI*F*L BY THIS WE CAN SAY IT AS LAGGING.
IF LOAD IS CAPACITANCE THEN THE CURRENT IS LEADING BY 90 DEGREES W.R.T VOLTAGE CAPACITIVE REACTANCE XC= IS 1/2*PI*F*C
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
how to carried out DAR test in 11 KV Alternator ?
although ckt breakers have taken the place of old fuse. But instead of it , these older ones are still used in the industries and homes ? why .... what are their advantages and disadvantages ? which one is leading and winning the race and competition ?
(1)WHAT HAPPENS WHEN SUDDENLY LOAD GIVEN TO THE INDUCTION MOTOR ? (2)CAN WE MAKE WOOD AS MAGNET ? (3)WHAT IS THE VALUE OF MAGNETIC FLUX DENSITY IN TRANSFORMER ? (4)WHY WE ARE USING ELECTROMAGNETI NOT ELECTROSTATIC IN MACHINE ?
What is an automatic controller?
Dear sir, my knowledge about cable size determination is limited. Though I read examples I could not calculate the Cable size required for electric driven pump 40 KW, 380 Volt, 50 HZ, 50 meter from transformer and it is three phase star delta starting. Please help as there is no one in my surroundings to help.
in shunt clippers why a resistor is used in sereis with the input
An active element is one which a. Supplies energy b. Absorbs energy c. Supplies energy and convert energy from one form to another
In HVDC LINE RECTIFIER CONTROL ON CONSTANT CURRENT AND INVERTER CONTROL CONSTANT EXITATION ANGLE CONTROL BUT HOW INVERTER CONTROL CONSTANT CURRENT?
how to select the isolation tranformer for siemens 802dsl cnotroller
What cmos is and its benefits?
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
what are the basic insulation levels & what its Unit
how copper and aluminium wires or cables are choose for current rating? please provide copper and aluminium wire selection chart for different current rating ?
how could we know the size of cable by physical view?