In annual maintenance we check the following points in oil
type transformer
1. We check the die-electric strenth of the oil.
2. We check moisture of the oil.
3. we check Be=reak down voltage of the oil.
4. We check the earthing of the transformer
5. We check Silica gel .
6. We calliberate all the relay like over corrent, earth
fault & differntial relay.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
what are the different methods for the starting of a synchronous motor.
How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V
What is the difference between line drop and percentage line drop?
In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?
i completed my DEEE. and i want to electrical c license. how to get it..?
How can we measure the residual voltage in dc machines?
IF I KNOW THE AREA OF CROSS SECTION OFTHE WIRE , WATTAGE OF THE LOAD ,VOLTAGE SUPPLY WHAT IM GIVING TO THE LOAD AND ALSO POWER FACTOR OF LOAD ....... SO GIVE ME FOR WHAT AMOUNT OF CURRENT I SHOULD USE WHICH TYPE OF CABLE?
how to find the resistance and gap volatage of the diode??
what is the easiest method of short circuit current calculation ? pls. derive with a mathematical example in real life application.
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
at which voltage level arcing ground is occurs ??????????
can you send me the placement papers of electrical engg. from companis like NTPC,DRDO,IOCL,HPCL,BPCL etc.?If,plz send as soon as possible.Thanks.
do any one help me to get "C" license,, i have doubts ,,, if mediators ter pls call me,, my no is 8056640042
why ct ,cvt should be stored in a vertical position?
How capacitor improves pf