what is the deference bitween DCS and PLC SCADA HMI System
for Power Process Industry.
Answer Posted / ramesh
DCS:- Actually DCS is used for redudancy ,it will have two controllers with master and slave concepts with communicating to the slave nodes and every nodes will be communicating with the particular node addresses.It will have larger no of analog I/o but in PLC is best for larger no DI/DO s,so in power industries we will use larger no of AI/AO s ,so we are going for DCS,and moreover in DCS the scanning time and the memory speed will be greater when compared with the PLC.We can use larger no of inputs and outputs in dcs whereas in PLC we cant use larger no because of lack in redudancy controller.So,in process industries if one controller is tripped then the second controller will take in to account and the plant will not get tripped.
| Is This Answer Correct ? | 9 Yes | 9 No |
Post New Answer View All Answers
Isometric drawings are generated during _________________ phase of a project
what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
What is the main difference between Cavitation and Flashing?
How will you calibrate an Absolute Pr.Transmitter of range 400mmHg absolute ?
Draw symbols of the following :
what is the imbustion control loop
Identification of control valve parts.
Explain types of valves?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??
how radio frequency level probes works with its controller ? what is its principle ? pls give me brief explanation?
how u calibrate pneumatic n motorized c/v?
all types of liquid analyzer principle with drawing?
why we are using magnet for calibration of gas detector?