Where double earthing is required? Is there any power
specification to have double earthing?
Answer Posted / k.prakashchandra
I think that IE rules insist on 'two distinct earth connections'
Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
what is basic difference betmeen normal & flame proof motor??
If symmetrical fault occurs at the terminal of a synchronous motor then how the motor will act...explain it..
1.Z transform always lies around ? a) origin b) pole c) zero d) z=1. Multiples Mcqs which is bother me can’t find answers on internet. Some help required with little explanation . Note: this is not homework or related to any test. Thanks
In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.
why we use Test Terminal Block in 11 KV and 33 KV electrical panels.
ELECTRICAL DRIVES: can a motor load system with passive load torque can have equilibrium speed in second quadrant
What is the difference between voltages or potential difference? And what are they?
In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.
Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
why we can stote dc? why we cant store ac?
what is the power factor used by the PHCN in nigeria? 2. what is the difference between an alternator and generator. 3. Generation of poweris in KV but how is transmission is in MW. 4.If the transmission of power is 20,000MW how can it be increaesed to 80,000MW
Can any one provide the inspection procedure of MIMIC for VFD panel? Details: If someone wants to have a mimic in the VFD panel what are inputs considered for the mimic(like on,off,trip) whether we are able to add speed variation in the mimic(if so how can we get) and what are the parameters to be checked in the MIMIC during inspection?
What happen to the transformer if the OLTC frequently used for lower and raise occured 50times daily?
how to check regenerative load in drived motor