In a generator (Synchronous) does the rotor speed
(frequency) corresponds to the speed of the water (in
hydro). does the torque on the turbine relate to the flow of
water?

Answer Posted / milinda

when we increase the flow of water (m3/s) by the governor
(controlling the AREA of the water inlets) we change the
torque on the turbine not the speed,right? but can we change
the output frequency changing the SPEED of the water flow ?

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

area control error

1293


Explain what is clipper and clamper circuits?

695


Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB

2315


What are locations arc protection relay is fixed.

1363


why we used ZNO in Lightning arrester.

1541






what is effect of length of air gap on performance of dc motor and generator?

1333


Where servomechanism is used?

642


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

1682


how you configure motorvision relay (L&T make)from DCS

4331


WHAT DO YOU MEAN THE DIFFERENT TYPE OF CURVES OF RELAY LIKE STANDARD INVERSE, VARY INVERSE, NORMAL INVERSE, LONG INVERSE ETC....

1545


please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5

1183


which pump used in STP

1669


3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.

2241


State the points to be considered for selecting a particular type wiring.

1636


How to calculate the heat load for a electrical room

2611