Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the factors considered for the selection of cable?

Answer Posted / nvyibrahim

1.Type of cable Instalation
2.Type of cable based on site requirments and techno-economy
3.Main operating ratings
4.Core arrangments cable size,Termination space available
5.shielding requirments

Is This Answer Correct ?    19 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between in Fourier series and Fourier Transform. and please tell me the difference between both of them and the why we use them in communication system?

2088


how u measure/calculate renge of capacitor,capacitor has no any rating tag.what is the theory of measure of capacitons.

2034


what is spadar bar .why I use in DC generator.

1975


what is a synchronizing lamp ?

1731


What is force on parallel conductors ?

1139


what is 30-phase of transformer

2361


What facility we get after CT secondary earthing and how?

2296


What is EHT tariff or Power factor Tariff ????

2391


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

2085


What is the formula to calculate the no load current of a single & three phase induction motor

2333


3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.

2712


ITI r/tv trade APPLY (J.T.O VACANCEY) ALSO INCLUD AITT ELECTRONIC,WRITEEN XAM DONE 23.03.10 BUT NO RESPONCE WHY ANATHER ID gopal_gh007@rediffmail.com

3472


What is the name of transformers oil filteration equipment?

2151


how to calculate the settings for shaft ct protn in hydro generators

2016


LET ME NOW MORE ABOUT icu and ics for circuit breaker. how we calculate the rating of circuit breaker and i c u and ics values

2933