Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is creepage distance in sub-station?

Answer Posted / deadzg_devil

Creepage Distance. Creepage is the shortest path between two conductive parts (or between a conductive part and the bounding surface of the equipment) measured along the surface of the insulation. A proper and adequate creepage distance protects against tracking, a process that produces a partially conducting path of localized deterioration on the surface of an insulating material as a result of the electric discharges on or close to an insulation surface. The degree of tracking required depends on two major factors: the comparative tracking index (CTI) of the material and the degree of pollution in the environment. Used for electrical insulating materials, the CTI provides a numerical value of the voltage that will cause failure by tracking during standard testing. IEC 112 provides a fuller explanation of tracking and CTI.1 Tracking that damages the insulating material normally occurs because of one or more of the following reasons:

*
Humidity in the atmosphere.
*
Presence of contamination.
*
Corrosive chemicals.
*
Altitude at which equipment is to be operated.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the lifetime of a Thyristor? Is there a recommended lifetime for thyristors after which they should be replaced?

2719


condition Autotrip facia come on control panel of electrical transmission line?

1580


Any one can explaination about calibration with rotating sub standards?

2075


kindly send me 11KV MV motor differential protection procedure by primary injection method.

1447


if any house we instaled a 1.5 ton ac and its phase cable of wiring is installed but netrual cable of wiring not instaed. my question is that is neutual of house(for other wiring is capable for ac load or a sepeart neutrual wiring required

2479


HOW CAN I GET 5CORE HO7 CABLE SIZE IF I HAVE 1800A?

2049


Why are cables rated for 40 KA for 0.25 Sec fault current rating?

1957


Hi I'm doing my MBA(3rd semester).I applied for the post of ET conducted by BHEL the last year.I cleared the written and lost in personal interview.Again I wrote the exam this time and cleared the written n yet to take the personal interview.Shall I disclose in the interview about my studies.What shall i say if they ask about my change from studies to job

2165


why magnet has north and south poles only why not east and west and why we are considering as north and south poles? why cant we consider as east and west?

2042


how we sesign the transformer give some specifion regarding design of transformers

1934


what is the use of permanent magnet generator in exciter

2171


why should the primary of transformer be connected in delta in a heat run test?

1989


any idea abt REVERSE METERING concept.........?

2247


why dc is used in control circuits for MV & LV switchgeras instead of ac

1967


A 100W electric lamp is supplied from a 115V, 60HZ source. The peak instantaneous power dissipated in the lamp filament is

2384