Answer Posted / venkat
calculate the Capacitve reactance (Xc) = V/I
Then apply the formula C ( in Farads) = 1/2*3.414*F*Xc
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets
i have done diploma and btech in EE and live in Chandigarh so kindly help me how can i make my competency certificate in my area.
How to calculate energy stored in an inductance?
Why back emf used for a dc motor? Highlight its significance.
What is the main purpose of c.f.b.c.boiler
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
where the lexical paramater will use in fron end?
How to test Alternator stability test for REF relay
What is meant by vector group
what are the interview question asked in wind mill about electrical
what is the write prosidure of stringing of 8meter pcc pole.
why the rotor current becomes in steady state during high slip region? please verify with equations.
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?
explain Density
In hydel power plants, L.A's, S.C's are placed inside the control panel boards. what is the purpose? [already the total body was earthed to ground.]