Dear all,
is ther any body who can tell me about the
setting of ACB(air circuit breaker ). what kind of it,s
setting is and how to do it,s setting. also please tell me
the setting of VCB(vaccume circuit breaker) . please tell
me their setting,s.
i will b very thank ful to all of u.
Thank,s and Regard,s.
Muhammed Ikram.
Answer Posted / karthik
Dear Mohammed,
1.MCB for normal commercial & household purpose and it's
having seperate cuurent transformer.
2.ACB is used in LT panel, which is protective device for
entire LT panel and it having current transformer.based on
ratting of CT, ACB tripping the supply voltage anf it's
having seperate current selector range.
3.VCB is used in I/p way or O/P of 11KV,22KV,33KV
transformers and it's operation is same for ACB
4.SF-6 is used in 110 KV and above and it's operation is
same as the VCB
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is zinc diffusion?
how synchronous condenser is used in place of synchronous generator with out negotiating IEEE standards? Can i use 3 generators as synchronous generators and 2 generators as a synchronous condensers in an IEEE 14 bus system with out disturbing the standards?
how to select the double earth conductor if 21A full load?
What type of DC motor would you see for a lift?
For a spring controlled governer the relation F = ar+b (F is the controlling force, r is the radius of rotation a and b are constants), indicates that the governer is
I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
Can we use BS 6651 and BS EN 62305 standards for computer room lightning ptotection in substation?
How two nos. 130 kw D.C motor get synchronise using D.C drive.
Draw the vector diagramme for Asynchronous Induction Generator at noload,half load and fullload.
In HI POT test what is reason for applying the AC VOLTS and DC VOLTS in different applications what is the nessesity for this ?
what is the basic need of domestic loads 1- voltage 2- current
State the other types of Air Conditioners?
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.
How can we measure earthing resistance test (Earth meggar) of Transformer neutral pit while in live condition?.
WHY EXCITER PHASE SEQUENCE ARE OPPOSITE THAN STATOR SUPPLY PHASE SEQUENCE IN SYNCHRONOUS MOTOR >