Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why 4 to 20 ma ,why not 0 to 20 or 3 to 15 or anything

Answer Posted / smruti senapati

with 0-20 ma you canot distinguish between minimum field
value and connection break.with 2-20 ma ,internal circuits
can distunguish between connection break of minimum
value.normally when the value is minimum the transmitter
will give you 4 ma while in case of connection breakage it
will give 0 ma...

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,

2125


What happen if I install my pressure transmitter below the elevation of pipe in natural gas service?

1188


If a warning lamp will operate with the ground circuit is bypassed with a jumper wire to ground, what should you check?

2073


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1934


what is the importance of CV in the control valves? how it is calculated?

2434


What is the purpose of the analyzer in petrochemical plant?

3864


on interface level transmitter model(RTG3302-EMERSON) What is threshold valve how can we select correct threshold value T1,T2,T3,T4 When interface water & hydro carbon

2143


What is Positive Calibration and Negative Calibration?

2242


List three types Level Switches with their working principles

2121


why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.

2728


what is the difference between active & reactive power?

2183


types of cable..? Use of every types of cable..?

2136


Specific gravity.

1863


State bernoulli’s application.

1137


Using your own examples solve a problem involving normal table. (experimental method and analysis)

1144