Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

i want to ask that as everybody knows that in star
connection on star point is called neutral. my question is
that why on that poin called neutral. what is the reason
behind it. what is the logic behind it. i heared somewhere
that on this point all phases current become zero thats
why. if this answer is right then prove why on that point
is current become zero. if this answer is not right then
tell me the right answer. post ur answer here or on my mail
address. m.ikram786@yahoo.com
m.ikram555@gmail.com.
thanks.

Answer Posted / kamlesh dewangan

In the three phase system all three phase current vector
sum to zero only if the system is balance (ie balance three
phase system).
_ _ _ _
I= Ir+Iy+Ib
These can be easily proved by solving following equation:
_
Ir = Im*sin(@)
_
Iy = Im*sin(@+120) Since in balance system all
phases are 120 degree apart
_
Ib = Im*sin(@+240) Since in balance system all
phases are 120 degree apart

_ _ _ _
now calculate I= Ir+Iy+Ib, it will become zero.



Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is steady state response?

1248


Why open circuit test of transformers is conducted at rated voltage??Why not any other voltage??

1615


What is your acheivements

2097


Mention the difference between Analogue and Digital circuit?

1078


We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

1931


Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.

1645


What is resolution of a measurement?

1137


what is meant by the phrase 'static load' in case of shorting in a generator excitation system?

2096


Why efficiency of generator is higher than motor at a particular load?

1998


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2657


what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors

1939


how was your last weekend.

1738


what work will do diffrential realay DG set

2824


What is meant by time harmonics and space harmonics?

2740


how to find Harmonics and types as per the equipemnts

1211