Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how much Watt can we fully load a transformer

Answer Posted / r a m e s h

Kw=Kva*0.8
here Kva=45
p.f= 0.8
hence the total load= 45*0.8= 36kw or
36000w

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is all the servo motors having brake?please specify which servo motors having brake for stop on position and which are not.

1773


What Normal(Tangent) towers and Tension(Cut-point) Towers?

6201


How to see the inductance in a transmission lines

2128


What is the minimum value of hfe for the oscillations in transistorized rc phase shift oscillator?

1255


how to compute kvar in substation feeder to improve power factor and sending voltage

2131


What is a difference between indoor transformer and outdoor transformer of same rating

5810


Dear All, I am new in construction company , my boss ask a question at time of interview , If we have 60MW generation and Single Power Transformer step-up we have. if CMR 50/60MVA , ONAN, ONAF respectively , is it sufficient or not ? for that much power to transfer,

1633


As we use capacitor bank in 3ph ckt to improve PF, can we use capacitor in single ph domestric use, in house we have Fan,Mixer,electric cooker,iron,tube choke they also lag the system,because it is inductive load. if it is possible to improve PF of single ph system-- if yes- type of capacitor to be used,connection diagram, working in detail. if no-- list it.

1767


Why do not we prefer non conventional sources of energy to conventional sources?

1192


given data are load current & power factor cable core size? plz any one update the calculation formula

1883


Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks

1756


how is the incoming cable size calculated for a given current rating of a panel??

1922


diff b/w elcb and rccb

2284


What kind of Neutral CT can be placed in 11/0.433KV transformer to be used and what are its specification?

1880


for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?

1954