Can u explain : what is supply for train (whether a,c or d.c
).I know that supply is 25000v a.c .But there is rumour that
supply is D.C.
And also explain how lights and fans inside the trains are
working ,and what type of motors are used in trains whether
D.C motors or induction motors .If d.c motor, how it gets
supply.If traction motors are used then what are traction
motors and its functions and how it differs from other
motors and also explain about locomotive .
please reply..............
Answer Posted / sharan dilip
Its good question.
But for a motor the mechanical characteristics (T Vs N) are
concentrated.and even though the if the load increases the
speed would decreases for shunt motor.But in the case of dc
series motor both armature current and field current are
same and at much higher loads also the torque can be maintained.
For dc series motor we operate in such a circumstances such
that at constant torque and variable speed.
Is This Answer Correct ? | 3 Yes | 2 No |
Post New Answer View All Answers
What is the basis for framing the rules of block diagram reduction technique?
standard earthing rating for power line..
Why we are using only Dyn11 tranformer in distribution system but not using a Dyn1 in distributing system?why not and advantage and disadvantage in both
How to calculate loses in transformer of 160 KVA ?
how hazordious area is classified at an oil & gas plant and categorise suitable class of electric equipment in that area like induction motors, LCS, Lighting Fixtures Fluerescent/Flood lights Mercury& sodium lights, J.Bs, Power Cables etc
sir vizag steel ka junior trainee ka paper kitne number ka ayega
Why we use Electrical energy rather than any other type of energy, mostly? Explain behavior of open secondary CT and short circuited secondary PT in energized condition?
How line capacitance & line inductance varies with increase in height tower.
sir i applied for hpcl(electrical).i want to know from which subjects most of the technical que will b asked.and pattern of the written test.pls help me
11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??
a 100mva,400/200v transformer has leakage impdce of 10% draws a steady state line currentof---------------
Role of active and reactive Power sharing in between two synchronized Generators, Droop Setting role ?
In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?
15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help
What is gross error?