i am a btech cs 2009 passout.
i am opting for mainframe course. is it good to do this course?
pls. anyone suggest me

Answer Posted / reddyp

Go for a SQL server DBA. Its has very good market in USA

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

IDENTIFICATION DIVISION. PROGRAM-ID. UPDT. AUTHOR.anbu. DATE-WRITTEN. AUG 13. ENVIRONMENT DIVISION. INPUT-OUTPUT SECTION. FILE-CONTROL. SELECT CMSTR ASSIGN TO CINP1 ORGANIZATION IS INDEXED ACCESS IS SEQUENTIAL RECORD KEY CM2-KEY FILE STATUS IS WS-CMSTR-FST. SELECT CTAB ASSIGN TO CINP2 ORGANIZATION IS ACCESS IS SEQUENTIAL RECORD KEY VSAM-WHSE- KEY FILE STATUS IS WS-CTAB- FST. DATA DIVISION. FILE SECTION. FD CMSTR. COPY RXCYFC20. FD CTAB. COPY AITYWHSE. ************************************************************ ****** *** WORKING STORAGE VARIABLES *** ************************************************************ ****** WORKING-STORAGE SECTION. 01 WS- VARIABLES. 05 WS-EB PIC X(02) VALUE ZEROES. 05 WS-DIV PIC 9(03) VALUE ZEROES. 05 WS-CMF-RECS-REWRITTEN PIC 9(01) VALUE ZERO. *** FILE STATUS VARIABLES *** 05 WS- FILESTATUS. 10 WS-CMSTR-FST PIC 9(02) VALUE ZEROES. 10 WS-CTAB-FST PIC 9(02) VALUE ZEROES. *** END OF FILE VARIABLES *** 05 WS-CMSTR-EOF PIC X(01) VALUE 'N'. 88 WS-CMSTR-EOF-YES VALUE 'Y'. 88 WS-CMSTR-EOF-NO VALUE 'N'. 05 WS-CTAB-EOF PIC X(01) VALUE 'N'. 88 WS-CTAB-EOF-YES VALUE 'Y'. 88 WS-CTAB-EOF-NO VALUE 'N'. **** ERROR VARIABLES **** 05 WC-ABEND-900 PIC 9(03) VALUE 900. 05 WE-ERR-CODE PIC 9(02) VALUE ZEROES. 05 WE-ABEND-CODE PIC 9(03) VALUE ZEROES. ************************************************************ **** ********* PROCEDURE DIVISON ********** ************************************************************ **** PROCEDURE DIVISION. 0000- BEGIN. PERFORM 1000-INITIALISE THRU 1000- EXIT. PERFORM 2000-PROCESS THRU 2000- EXIT UNTIL WS-CMSTR-EOF- YES. DISPLAY 'WS-CMF-RECS-REWRITTEN :' WS-CMF-RECS- REWRITTEN. PERFORM 5000-CLOSE THRU 5000- EXIT. GOBACK. 0000- EXIT. EXIT. 1000- INITIALISE. OPEN I-O CMSTR. EVALUATE WS-CMSTR- FST WHEN 00 WHEN 97 CONTINUE WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CMSTR-FST MOVE WS-CMSTR-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE. OPEN INPUT CTAB. EVALUATE WS-CTAB-FST WHEN 00 WHEN 97 CONTINUE WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CTAB-FST MOVE WS-CTAB-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE. 1000-EXIT. EXIT. 2000-PROCESS. READ CMSTR. EVALUATE WS-CMSTR-FST WHEN 00 CONTINUE WHEN 10 SET WS-CMSTR-EOF-YES TO TRUE GO TO 2000-EXIT WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CMSTR-FST MOVE WS-CMSTR-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE IF CM2-RECORD-TYPE-SOLD-TO MOVE CM2-ENTERING-BRANCH TO WS-EB PERFORM 3000-READ THRU 3000-EXIT UNTIL WS-CTAB-EOF-YES END-IF. 2000-EXIT. EXIT. 3000-READ. MOVE WS-EB TO VSAM-WHSE-CD. MOVE 'WHSE' TO VSAM-WHSE-ID. READ CTAB. EVALUATE WS-CTAB-FST WHEN 00 MOVE WHSE-DIV-CODE TO WS-DIV PERFORM 4000-REWRITE-CMF THRU 4000-EXIT WHEN 10 SET WS-CTAB-EOF-YES TO TRUE GO TO 3000-EXIT WHEN OTHER DISPLAY 'ERROR IN READING TABLE FILE: ' DISPLAY WS-CTAB-FST MOVE WS-CTAB-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END- EVALUATE. 3000- EXIT. EXIT. 4000-REWRITE- CMF. IF WS-DIV = 250 OR 252 MOVE 'F' TO CM2-FREIGHT- TYPE MOVE 1 TO CM2-FREIGHT-THRESHOLD- AMT ADD +1 TO WS-CMF-RECS- REWRITTEN REWRITE CM2-SOLD-TO- RECORD DISPLAY 'RECORD UPDATED' END- IF. * EVALUATE WS-CMSTR- FST * WHEN 00 * CONTINUE * WHEN OTHER * DISPLAY 'FILE NOT UPDATED' * DISPLAY WS-CMSTR- FST * MOVE WS-CMSTR-FST TO WE-ERR-CODE * PERFORM 9999-ABEND-PARA THRU 9999-EXIT * GO TO 4000-EXIT * END-EVALUATE. 4000-EXIT. EXIT. 5000-CLOSE. CLOSE CMSTR CTAB. 5000-EXIT. EXIT. 9999-ABEND-PARA. COMPUTE WE-ABEND-CODE = WC-ABEND-900 + WE-ERR-CODE CALL 'ILBOABN0' USING WE-ABEND-CODE GO TO 5000-CLOSE. 9999-EXIT. EXIT. 5000-CLOSE. CLOSE CMSTR CTAB. 5000-EXIT. EXIT. 9999-ABEND-PARA. COMPUTE WE-ABEND-CODE = WC-ABEND-900 + WE-ERR-CODE CALL 'ILBOABN0' USING WE-ABEND-CODE GO TO 5000-CLOSE. 9999-EXIT. EXIT. //this program is giving maxcc=0, but not updating..

3413


what is difference bt COND, REGION & TIME parameters at JOB & EXEC. give an exp.

8492


Mention the guidelines to write a structured cobol program?

704


What is the problem of ordered sequential files access?

811


What is the difference between Global and External Variables?

768






Hi pls anybody tell me about " ANALYSIS DOCUMENT PREPARATION AND ESTIMATION OF TASK " (in real time project)."I want to update a sequential file in my project" for that purpose i need both structures i mean analysis document and estimation of task.

1785


What is link edit in cobol?

858


what is the difference between COBOL2 AND COBOL390?

2566


How to print 10 to 1 if the input have only 10 digit number?

919


How to use the same COBOL program in Batch and CICS on lines? explain with an example

2007


What is the difference between PIC 9.99 and 9v99 in COBOL?

850


which is Best IBM Mainframe Training and Placement Institute in Ameerpet Hyderabad

1115


) what is the difference between AID and HANDLE AID?

1742


What do you understand by psb and acb?

752


i need a small 3d program using inline and outline.

1748