Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why there is a need of optical activity & specific optical
activity measurement by polarimeter

Answer Posted / ravali

to identify a compound both or and sor r required.bcz SOR
depends on OR where as OR changes with concentration ,so
not stable.SOR=OR/C*Lwhere c=concentration,L=cell
length.for a unkown compound of known concentration SOR
does not changes with cocentration,so we can identify the
compound.

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Which parameter require to do for analytical method equivalency?

818


In which situation we require to prepare the standard solution from sample in Related substance method?

822


how to decide for one product require water content or LOD?

836


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

1959


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2889


what is turbidimetric titration?Give 2 examples.

2730


how pda detector works over uv?

778


What is the difference between purge septum flow and column flow in gas chromatography?

2643


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

974


mahagenco syllabus for the post of chemist

6512


why are measure gas flow " ml " in Gas chromatography

1699


using gradient pressure in gas chromatography are not ?using gradient pressure why

3439


how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,

2649


Tell me about analytical method validation in QC

6236


how can I make the copper get white bye any salt or acit?

2264