Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between c-8 and c-18 column

Answer Posted / s.goutham

the c18 coloumn wsa highly non polar compared to c8
coloumn.Most of the compound well seperated in c18

Is This Answer Correct ?    5 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

864


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1603


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2578


What is the formula to determine the concentration of M of a solution given the % transmittance? Use %T = 43.7 as an example.

2690


Why we use potassium dichromate in uv calibration Exact reason behind it??

1263


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1865


what are the guidelines for analytical method validations?

1108


How can I develope method of dissolution by HPLC OR UV

2409


Why to use propyl paraben in HPLC gradient calibration

7494


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

6074


Why sodium hydroxide used for maintain pH of phosphate buffer

2419


what is mean by 40 in the dissolution basket mesh size?

791


how require to set assay concentration for standard and sample?

929


Why perchloric acid used for potentiometric titration

2685


what is mean by dissolution hydrodynamics?

831