What is difference between slip rings and carbon burushes?
Answer Posted / manasa
> slip rings are segments which is made of hard drawn
copper and carbon brushes collect the emf from the copper
segments.
> carbon brushes are used both AC and DC machines but slip
rngs are used only AC machine.
> in DC MACHINE split rings are used.t is also called
commutator(combination of split rings)
| Is This Answer Correct ? | 12 Yes | 4 No |
Post New Answer View All Answers
Compare jfet’s and mosfet’s.
kindly send me 11KV MV motor differential protection procedure by primary injection method.
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
we are having 15kw and 3kw motor both can run in same time , instead of using copper we are using ug aluminium cable , 35 sq.mm is suitable for its current carrying capacity..?
if a.c supply is given to the motor,, what happen?
what should be the ideal gauge of wire (In sq mm) for different loads in Ampere?
please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5
What is the principal of motor?
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?
given data are load current & power factor cable core size? plz any one update the calculation formula
How can we calculate the KVA rating of a Distribution transformer from its core details?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
How to calculate total harmonic distortion level(THD) in VFD? and how can we reduce harmonics?
how ct burden,magnetising current,ratio and knee point voltage are related & derived
draw the block diagram of fire alarm?