what is the difference between concentrated winding and
Distributed winding in motor?
Answer Posted / sanni kumar
in concentrated winding all the winding turn are bound
togater in series to form one multiple coil ex-transformer ,
d.c machine.in distibuted winding all winding turn arranged
in several full pitch or fractional pitch ex-in induction moter
| Is This Answer Correct ? | 16 Yes | 9 No |
Post New Answer View All Answers
how to calculate power consumption in slip ring motor at different step
WHAT IS FAULT CAPACITY OF HT MOTOR TERMINAL BLOCK? ANY BODY HAVE ANSWER PLZ....POST IT.
Sir, I have applied for the of Assistant.engineer of NPDCL. please send me all AP TRANSCO AND JENCO solved papers of previous exams . I requested send me the papers to my id as soon as possible (rajanikanth_peddi@yahoo.co.in) (This is very urgent) Thank You,
give single line diagram of D.G distribution form alternator to main L.T panel?
Is there any abbrevation for STUB in Stub bus protection
Could Please Explain briefly. Why used stabilizing resistance series with High impedance bus differential protection relay.
How can find thermal state value in relay for calculate thermal overload.
explain which quantities change in the starting and the and the running condition in induction motor
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Why in metering Ct for ammeters ct secondary side is grounded for each Ct but not in case of CBCT (Core balance current transformer)..kindly some1 highlights the reason..is it because net flux is zero?
what is difference between 5A and 100A CT constructional wise and operation?
Grid fault level [KA]?
How to calculate MCB Breaking capacity.
Why can't we parallel the secondary circuits of two voltage transformers?
What is Harmonics how it is produced and what is the method to control the same