What means zero and span in transmitter callibration.
Answer Posted / eng\ ahmed saleh
ZERO : Is The LRV "Lower Range Value" of the transmitter
SPAN : Is The URV "Upper Range Value" of the transmitter
| Is This Answer Correct ? | 23 Yes | 43 No |
Post New Answer View All Answers
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
Calibration of controller (pneumatic)
Questions on flow meters,few questions on HART protocol,
the 3 most common transmitter protocol being in refinery or qatar gas and aramco.
what is the vital subject for scoring bhel exam&what is the question pattern
Difference between ultra sonic flow meter
how to calibrate load cell
our kks tagging is crossing more than 12 character please suggest how to take tags in the DCS
please someone tell me what is function of vibration sencer and how many types and how to control viberation.please. my id is jimmykhan077@gmail.com
How does your previous experience relate to the job you are applying for ?
How to Calibrate Vibration Probe (Axial, Redial) in field
the output of the common trasmitter protocol in qatar gas are the following
Pl send the model question paper of mahagenco account officer post
Name different parts of a pressure gauge.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =