What is the maxi. percentage of steel in compression
memeber of C/s area & what is minimum dia for compression
member as per IS 456:2000?
Answer Posted / tusharpatel18
AS per IS 456:2000,Maxi. percentage is 6% of C/S area of
member.However it is limited to 4% in considering spacing
between bars & pouring of concrete.The minimum bar dia for
compression member is 12mm.
| Is This Answer Correct ? | 26 Yes | 0 No |