What means zero and span in transmitter callibration.
Answer Posted / rakhi n
Above explained is zero adjustment of transmitter,
Span of transmitter is
say is above transmitter is of range 0 mmH2o to 5000 mmH20
than span of transmitter will be 5000 mmH2O
sometime we do have negative ranged tnansmitter like -20
bar to 20 bar in this case span willbe 40 bar.
| Is This Answer Correct ? | 41 Yes | 6 No |
Post New Answer View All Answers
how do we commission inergen system?
Sir,I am going to sit for IOCL written test exam. recently.Can anyone tell me the name of 'Objective type Question Book on Instrumentation Engineering ' which will help me. Pl. mail to bidyut_71@rediffmail.com / bidyut.saha2008@indiatimes.com / bidyut.saha09@yahoo.in
(1) In turbine, what does term CDP, NI, NH, HSSOC, means. (2) What is the purpose of LO overhead tank in turbines.(3) An equipment is certified for EEX, IA, IIC,T6, what do you under stand by this.(4) what is SURGE, and how it is prevented, what is the purpose of bypass valve across AS valve.(5) Give 2 application of quartz crystal used for process parameter measurement.(6) what is meant by cold float of compressor shaft. (7) state four different types of flow measurement. For gas flow measurement mmscfd is the common unit. Expand the unit and specify significance of word S in the unit.(8) what is meant by Gap voltage, in vibration measurement. Normally how much Gap voltage is set and state the reason.(9) what will the new flow factor if D/P transmitter is Re-Ranged from 25” wc to 50” wc.(10) what is the usage of QDV & Volume booster.
i am preparing for BARC ,so plz mail me how to prepare for BARC. ALSO IF POSIBLE SOME RELATED QUESTIONS. MY MAIL ID IS khushi_4uall2003@yahoo.co.in
Which Signal hart communicator work? If there any signal change when hart connect while transmitter in line ?
please send data bank of quetions answers on analytical instrumentation.
Why thermo wells are used? What materials are used in thermo wells?
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?
Question on maha cement
Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .
in mass flow meter what is drive friquancy ?
Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...
What are different types of orifice plates?
What is compensation for flow ? Why we use compensation ? What are the factors of different compensation ? We not use then what problems may happen ?
Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell