Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Explain why machinery used on a.c supply is usually rated
in KVA instead of KW?

Answer Posted / manugirl

t is because machinery used on ac supply are transformer regulated and the certainty that transformers are rated in KVA so as machineries used on ac supply should be given contained by KVA rating.
AC supply machines are rate in KVA . The total power consumed or supplied by the system depend up on the power factor of the load. As you know KVA= KW / Power factor.KW will cash for power factor.

Also size of a AC system is depend up on the insulation requirement (depend upon voltage) and size of conducting material( depend upon the current) so Voltage x current will give VA or Size of AC system
All AC power sources like transformers, generators, inverters etc. are usually rate in KVA.

The reason is that surrounded by the case of a power source, you cannot predict the type of load (resistive, Capacitive or Inductive) that will be connected to it. Hence the actual usable size rating depends on the power factor of the load.

Power = Voltage x Current x Power Factor

If the load is resistive, PF is 1 (unity) and if the nouns is inductive, it will be less than unity.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why the difference arise between HT reading & LT reading (submeters fixed in complexes, apartments etc)if the power factos exceed from 0.9 to 1 can the ht meter reads fast?

2912


What is the function of NER and NET?

2412


any one guide me to reduce the power factor of diesel Generator from 0.97 Leg to 0.8 Leg.with out any change in my load.

1639


Suppose a 3 phase, 2 pole, 440V induction motor is driving a flywheel of 600mm diameter, 150kg mass. By using v-belt and pulley, the speed is increased to 4500 RPM. What will be the effect on motor current?

1361


which network topology offers the greatest level of tolerance?

2100


what is meant by moulded case circuit breaker ?

2152


Draw the circuit of clapp oscillator?

1097


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

1974


i am in need of AC SYNCHRONUS MOTOR 30KW. ANY ONE KNOWS THE MANUFACTURER OF SAME. ALSO MOSFET AC CONVERTER 20KVA CONT.OUTPUT.

1889


What is the de rating factor of cable? What is the importance of the de rating factor in cable selection?

2052


how to compute kvar in substation feeder to improve power factor and sending voltage

2108


Operation of isolators.

1854


Can Anyone suggest the Standards (IEC or IS) for selecting copper current density?

1369


how can we change the phase angle b/w two phase?

5098


i want to model paper for section engg.

1978