Explain why machinery used on a.c supply is usually rated
in KVA instead of KW?
Answer Posted / manugirl
t is because machinery used on ac supply are transformer regulated and the certainty that transformers are rated in KVA so as machineries used on ac supply should be given contained by KVA rating.
AC supply machines are rate in KVA . The total power consumed or supplied by the system depend up on the power factor of the load. As you know KVA= KW / Power factor.KW will cash for power factor.
Also size of a AC system is depend up on the insulation requirement (depend upon voltage) and size of conducting material( depend upon the current) so Voltage x current will give VA or Size of AC system
All AC power sources like transformers, generators, inverters etc. are usually rate in KVA.
The reason is that surrounded by the case of a power source, you cannot predict the type of load (resistive, Capacitive or Inductive) that will be connected to it. Hence the actual usable size rating depends on the power factor of the load.
Power = Voltage x Current x Power Factor
If the load is resistive, PF is 1 (unity) and if the nouns is inductive, it will be less than unity.
Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
what is Different between Bilinear and Unilenier?
howmany electrician should maintain for a 1000 kva used plant... in kerala..
Write the force balance equation of ideal dashpot element.
Why the dc voltage drop during starting of emergency lube oil pump? The Voltage drop from 135kv to 125 kv for one min. before re-establish to 135kv?
The slip during plugging operation is given by= A 1-s B 2+s C 1+s D 2-s
can any one suggest me the tilt angle of my solar pannel ?? or tell me how can i know the fix tilt angle of my solar pannel?? my cordinates are 31.503629,72.993164.
how calculated Transformer losses.
what is meant by carrier aided trip protection in transmission line
Earth is a conductor or load?then ammeter connect to 3- phase supply,it shows the measurents or not?
what is the illumination level required for child play area?
In power transmission using open belts or horizontal shafts it is preferable to have the slack side of the belt on the top because
WHAT IS LOAD CELL
Metal covered multiconductor cables shall employ a marker tape located within the cable running for its complete length in lieu of cable surface marking. Is it true or false?
A 10 MVA, 66KV, 50Hz, Y-connected 3-phase alternator has synchronous reactance of 0.635 Ù. It is working at full load at 0.8 lagging p.f. condition. Find torque angle, neglect armature resistance.
Why 3 phase induction motor getting supply in body if one of it's phase is cut