what is the difference between inductive load and capacitive
load?give me some examples in general
Answer Posted / naresh
An inductive load is one in which load current lag the load
voltage and in capacitive load load current lead the load
voltage.
Example of inductive load: Fans,electrical motors etc.
Example of capacitive load: Battory, capacitor bank(used to
improve power factor)etc.
Is This Answer Correct ? | 6 Yes | 3 No |
Post New Answer View All Answers
Hi, This is Laila. I am selected for syndicate bank interview. Could you please share your views and the questions asked if you have faced the interview My email id is laila_honey09@yahoo.com Please send as fast as u can.Thank You Thanks... Laila.
what is the use of permanent magnet generator in exciter
hi frnds...pls send me aptransco previous papers .....pls..pls,,,(madhar.rocking@gmail.com)and suggest me some websites
what is upper impedance and lower impedance of a distance relay
When is lag lead compensator is required?
SUTIABLE FOR ohm's law super conductor
how we calculate the short circuit capacity of the busbar in LV & HT?
Phase control and integral control are used for?
defult setting in p220 micom motor proction relay for 11kv,640kw,f.l.a.-40a,1440rpm ht motor?
How does a television work?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
what is motor capacity of 80TR chiller? and also say what is the formula related temperature, motor capacity, TR?
what is meant by class 1 E in electrical power supply?
I need the recommended size for a 3 phase transformer at 13.8 KV Primary and connected loads of 3000 kVA at 4200 volts and 2375 kVA @ 480 volts AC.
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks