what is the difference between inductive load and capacitive
load?give me some examples in general
Answer Posted / naresh
An inductive load is one in which load current lag the load
voltage and in capacitive load load current lead the load
voltage.
Example of inductive load: Fans,electrical motors etc.
Example of capacitive load: Battory, capacitor bank(used to
improve power factor)etc.
| Is This Answer Correct ? | 6 Yes | 3 No |
Post New Answer View All Answers
where was current transformer protection units used and why??
i have gear oil pump with single phase motor.some time its motor starts running in reverse direction rather than forward direction...whats the reason behind this issue. 1- either capacitor is week? 2- or winding is week?
How do I calculate a WTI CT ofa 1250kVA 6600/400V transformer
is it possible to test of bus bar in high rise building without completed full floor ?
if 6 earth pit value is 1.5 ohm then what should be the number of earth pit to make the value .8 ohm
How much inductance or resistance require as a starter in series with induction motor of specific capacity(e.g. 5 hp) ? What is formula for it ?
HOW TO SET THE EARTH FAULT SETTINGS IN ACB????????????
Draw the line diagram of diffretial relay connected to transformer?
What is the gross weight to copper ratio in slip ring induction motor of 4000 HP,6.6 kv, 372amp, 992 rpm GE motor.
How earthing of switchgear system to be done.
Explain the iniluencc of short circuit ratio on the pert'orniancc of synchronous machine.
An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
How impulse levels are calculated that for 11kV impulse is 75kvp, for 24kV impulse is 125kvp ?
Why Stabilising Resistor used in REF circuit ?