why we generate transmit and distribute electrical supply
in multiple of 11
Answer Posted / kmsnow@yahoo.in
the ans is form factor (FF). The form factor is 1.11 for
sine wave . while we are calculating the voltage produced by
the generator we are using form factor for the same. so all
standard voltage ratings in world are of multiples o 1.11
| Is This Answer Correct ? | 8 Yes | 6 No |
Post New Answer View All Answers
what you have to see after one week or month from the day of installation of transformer ?
what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?
Do inductive loads have distorted current waveforms ?
1. The DC generaror,s induced output emf is connected with a DC motor(as load). when increasing the load of the motor by using brake drum or any way. what are the parameters will changes in both motor and generator(voltage, current, resistance, frequency, speed, torque, power, flux etc...) 2. Similarly for AC generator and AC motor 3. similarly if using DC batteries instead of DC generator, What happens?
how generator load test is conducted?what are the steps?
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
Differenciate between circuit wiring and sub main wiring with illustrations
draw 3 phase rectifier diagram
what is the difference between vector scale and vector diagram?
How to find ampere on ht side for selection of cable size ???
what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero
how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)
How line capacitance & line inductance varies with increase in height tower.
why don't we use the generator as a motor? and what will happen?
Why slip ring ind. motor power consumption is low compare to induction motor .same 90 kw motor used same load output