Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the problem with single phase AC motors and how is
it overcome?

Answer Posted / shahidniazi

when we use only single winding then no rotating flux so in
single phase motor is not actually single phase but split
phase mean 2 windings so that will produce rotating field
and rotor will move.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please send me jindal previous aptitude and technical question and answer.my email id is deep_raj@live.com

1979


why HT armoured cable does not glanding

4242


how to calculate the earth mat design in 132 kv substation yard ????

6248


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2191


what is the step by step formula for calculating bus bar phase and neutral size of a panel board.suppose the incomer of panel board is 100A..???step by step answer please

3770


block diagram of 2 ups system connected in parallel mode?

2082


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2118


While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?

3550


can I improve the furnace power factor (10 mva transformer) by adding a capacitor bank before the transformer.Does system power factor vary a lot with the furnace PF?

2050


how to test reverse power trip?

4475


How to calculate the sag of OPGW during stringing???

2589


how we calculate the dick for a pole?

2186


sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance

2100


What about electrical Units. discrive in detail

2098


What are hrc fuses and where it is used?

1188