.if the vector group of two transformers is not same n tey
r connected in parallel operation then what will happen?

Answer Posted / parashar.anil1

a circulating current will flow through the transformers
and the bus.....but if the vectors are very much differet
then it will behave as short circuit and a heavy blast may
occur.....

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to select HT/MV cable size ?

2005


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1501


What is the difference between earth fault protection of motor feeder with CBCT and Without CBCT ?

2295


what are factors to be consider in electrical installation like load factor,diversity factor .....

1369


On what basis do you decide the ONAN (Oil Natural air natural) or Dry type transformer for a project?

1172






WHTA IS LIMT OF LEAKGE CURRENT OF 11 KV 1 CORE 1000SQ.MM. XLPE CABLE.LOAD ON CABLE IS AROUND 600AMP .LENGTH 500 MTRS.

1673


hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com

2402


operation of protection relay watchdog contact?

1947


what is under coal gassification?

1640


what is basic difference betmeen normal & flame proof motor??

1491


What is meant by turbo alternators?

658


What are the basic elements used for modeling mechanical rotational system?

625


1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.

1490


what is the saturation point of crgo lamination.

1645


Block diagram of Power line communication?

1887