.if the vector group of two transformers is not same n tey
r connected in parallel operation then what will happen?
Answer Posted / parashar.anil1
a circulating current will flow through the transformers
and the bus.....but if the vectors are very much differet
then it will behave as short circuit and a heavy blast may
occur.....
Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
How to select HT/MV cable size ?
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
What is the difference between earth fault protection of motor feeder with CBCT and Without CBCT ?
what are factors to be consider in electrical installation like load factor,diversity factor .....
On what basis do you decide the ONAN (Oil Natural air natural) or Dry type transformer for a project?
WHTA IS LIMT OF LEAKGE CURRENT OF 11 KV 1 CORE 1000SQ.MM. XLPE CABLE.LOAD ON CABLE IS AROUND 600AMP .LENGTH 500 MTRS.
hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com
operation of protection relay watchdog contact?
what is under coal gassification?
what is basic difference betmeen normal & flame proof motor??
What is meant by turbo alternators?
What are the basic elements used for modeling mechanical rotational system?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
what is the saturation point of crgo lamination.
Block diagram of Power line communication?