In a transformer, the hysteresis and eddy current losses
depend upon
1.load current
2.maximum flux density in core
3.type of lamination
4.supply frequency
The correct statements are
(a) 1 and 3 (b) 2 and 3
(c) 1 and 4 (d) 2 and 4

Answer Posted / nawal kishor

(d) 2 and 4

Is This Answer Correct ?    10 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

from generating station If 400v LT line length is 1000m how much voltage is drop and how do i calculate it? which cable will be use for this line?

1626


(1)WHAT HAPPENS WHEN SUDDENLY LOAD GIVEN TO THE INDUCTION MOTOR ? (2)CAN WE MAKE WOOD AS MAGNET ? (3)WHAT IS THE VALUE OF MAGNETIC FLUX DENSITY IN TRANSFORMER ? (4)WHY WE ARE USING ELECTROMAGNETI NOT ELECTROSTATIC IN MACHINE ?

1764


what is the Pickup/drop off ratio in BCPU relays

4274


What is a surge supressor why its is used in synchronous generators

1619


which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant

1563






Trafo ratio is 11kV/6.6kv,Vector group is YND11. What will be the effect if secondary is used for earthed system.

3473


what r the checklist while installing 500 kva transformer

1923


Mention the difference between Analogue and Digital circuit?

789


please tell me, how i clear the objective test? when i studied form the one book after i solved the objective ,that time i solved that qes. but if i tried solve objective form the other book then i could not solved these que.

1334


generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...

1628


in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?

1512


how make megger test for control cable like 12c x 1.5mm and what it apply voltage and test timing details.

1843


how to calculate vfd o/p voltage by frequency

1814


What are locations arc protection relay is fixed.

1453


What is the drawback of static coefficients?

1083