Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we create vaccume in transformer tank before oil
filteration?

Answer Posted / k.prakashchandra

To dehydrate the windings.In view of high level of water /
moisture content in insulation ,it is recommended to
thoroughly dehydrate the windings by subjecting to vacuum
heating and drying after untanking the oil.Care should be
taken to see that the tank would not buckle due to the vacuum.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is dynamo?How it works and what is the function of dynamo in a DG.

2158


what is the difference between gas group b and gas group c electrical equipment construction wise?

1860


Difference between transition and diffusion capacitance

2965


how to calculate insulation level of transformer?

1682


how much UPS neutral erath leakage current.

3720


how to calculate cooling requirement of datacentre from electrical load?

2396


what is magnetizing and demagnetizing current in generator and motor?

3268


An active element is one which a. Supplies energy b. Absorbs energy c. Supplies energy and convert energy from one form to another

2051


WHAT IS MOBILE SUB-STATION? & REALLY BENEFIT IN INDIA

2066


what are the condition that makes hooter blow?

2438


What is the formula for selecting the cabels according to load? How to calculate what sq.mm cabel to be used?

1487


my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.

2047


what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?

1927


at meter room 50 hrc switch installed,but there are not get earthing proper,so what happen?and 11kv transformer out put going in to hrc main 400a three nog each? so earthing is require for all switch? (some customer made earthing at there home.)

1900


Why the moulded plug comes with domestic appliances instead of assembled plug like anchor, Vinay 5/15 A.