Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how peak can be sharp in hplc when it is come flat

Answer Posted / sasikumar.r

1. increase the concentration of organic phase. i.e.,
increase the ratio of organic phase in mobile phase

2. Add little amount of peak modifiying agent TRIETHYLAMINE

3. just REVERSE the column

Is This Answer Correct ?    15 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in sampling of raw material which side is pasted sampled labels

1828


what is classification of elemental impurities? what is risk assement in elemental impurities?

752


using gradient pressure in gas chromatography are not ?using gradient pressure why

3382


for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol

6058


How do we fix the sample concentaryion in hplc method development?

1132


why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space

2259


in each media we require to use SLS? how to proceed?

773


How can the GC or HPLC method is selected to determine the impurity profile in drug product?

7586


how you determine moist.of NaOH sol or NaOH flacks

2209


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1766


calibrtion procedue of LC-MS

2705


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

971


What is diffrence between extractable volume and deliverable volume? Answer pls

4554


If suppose 10 methods of dissolution given in pharmacopoeial for single content product then which method out of 10? or all 10 require to follow?

983


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1587