what is the difference between RTD & TERMO COUPLE?

Answer Posted / binod bhanj

The most notable difference between a thermocouple and an RTD is the principle of operation and manufacturing. A thermocouple is made of two dissimilar metals joined so that a potential difference generated between the points of contact is a measure of the temperature. An RTD, operates on the principle that electrical resistance of certain metals changes in a predictable way depending on the rise or fall in temperature. The two measurement tools each have their own advantages and disadvantages.

Advantages of the thermocouple include a wide range from -300°F to 2300°F, fast response time (under a second in some cases), low initial cost and durability. Overall, thermocouples are able to withstand rugged applications. Disadvantages for thermocouples are their wide accuracy range, especially at elevated temperatures, difficult to recalibrate (seeing as though they are dependant upon the environment) and, finally, installation can be expensive if long lengths of thermocouple wire are needed.

On the flip side, advantages for RTDs include stable output over a long period of time, ease of recalibration, and accurate readings over narrow temperature spans. Disadvantages, when compared to the thermocouples, are: smaller overall temperature range ( -330°F to 930°F), higher initial cost and they are more fragile in rugged, industrial environments.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between electrical earthing and electrical grounding?

690


how to check avr of dg set of 125kva

2155


if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer

1472


Why induction motor is widely used in industry

2267


How much ph is maintained of water electrolyte which is used in LRS for 1200 kw slipring induction motor ?

1258






Greeting to all members, How to calculate spill current when we have different ratio CT and Class for REF(Low Imp) I have 500/1A 5P20 @line side n 400/1A CL.X @ Neutral.

2551


what is induction furnance? how many phase supply given io its coil for 15 or 20 ton furnance?

2657


WHY IL=IPH IN STAR AND WHY IPH=IL/1.732 IN DELTA? WHAT IS REASON BEHIND IT?

5596


What is a single phase autotransformer?

647


how to find three phase complex power in per unit and MVA?

1652


Please brief me about number of pole in alternator.In single phase alternator coils are connected in star or series. How to calculate frequency for the same.

1427


What is the unit of magnetic flux density?

716


What is Instantaneous Earth fault relay,how will work

1690


why high speed tripping relay is used in protection circuit why not normal relay

857


dg started in plc mode and load taken later one battery terminal connection will be disconnected by loose connection what will happen for dg and shall we connect battery terminals while dg in load time?

1528