Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what happens when the transformer is connected to DC supply?

Answer Posted / dharmans

when we r transformer connected to the DC supply it 's
winding should be burnt. because, in DC supply there is no
back EMF. when there is no back EMF then the primary winding
get higher current then the winding will be burst. so any
were any time we don't connect the DC supply to the
transformer.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how does a submersible pump work..?

1971


why the rotor current becomes in steady state during high slip region? please verify with equations.

1995


sir vizag steel ka junior trainee ka paper kitne number ka ayega

2249


What is non-minimum phase transfer function?

1312


when we have to purchase the transformer by own i.e how much load will preferred HT connection?

1677


lenz law application and define

2843


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2154


what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?

2399


what is your aim

1930


a governer in an Ic engine controls the

1199


give me a clear defination of inductance,and how can u calculate inductance of a motor

2804


I am having dual speed motor of cromton greaves make of 3.7 KW -1400 rpm and 5 KW - 900 rpm. Please let me know groups and winding connction for rewinding purpose.

1932


Determine the BTU size of an aircon for 20 sq metre room

1884


What type of fittings and electrical accessories can be install in radiation area ?

1766


can u tell me the promotion from oiller to enginer

1949