Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why there is a phase shift lies between primary and
secondary voltages of a transformer?

Answer Posted / suresh

the main reason for phase shift is flux,because of some
leakage magnetude is dec.and also phase shift is prodused

Is This Answer Correct ?    0 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the resistance of the field winding of a d.c. Shunt generator kept low?

1108


grr resistance & contrator malt continuous

2138


A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1901


how do u gauge the size of the cable ?for eg. consider a 300 sqmm L.T Cable.How do u determine the size of the cable seeing it pratically?

2104


what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth

1379


What is the difference between isolators and electrical circuit breakers? What is bus-bar?

1143


What are the specifications for conducting earth leakage test as per IEC standard?

2053


Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!

2088


How many types of protection relays are there based on the characteristic?

1078


What is the Current equation in series RLC circuits.

1041


What are the types of windings according to the construction?

1114


What are root loci?

1086


How we can calculate the Amps for the cable Ex:- For 1sqmm wire how many amps we can draw (calculation)

3185


what is the range of maximum DOL and SDS can be use for pump and fan application

1110


hi frnz,can somebody give me any project work? i am a 2nd year student & interested in practical works...plz give me some projects

1990