why we can't use more then 50 hz in india ? Is it possible ?
Answer Posted / p.k.ghosh
50 Hz frequency is the britis system and every component is
manufacturing since that time it self to work by this
frequency.
We know that Ns=120f/P or f=Ns*P/120, P=2,4,6,8 etc. & Ns
we can adjust by adjusting the speed of Engine which
coupled with alternator so that f comes to 60 or other
frequency.Hence it is possible to generate the frequeny
other than 50 Hz.
Now if f = 60 or others, then loss will be vary
accordingly, insulation / dielectric loss,dimension of the
all equipment, all machines which is using for manufacture
of electrical component has to change. In other words all
the existing M/Cs has to modified from root it self , which
is not possible for a single day. Hence excisting m/cs are
using at 50Hz.
| Is This Answer Correct ? | 24 Yes | 0 No |
Post New Answer View All Answers
Define filter?
When the relative speed between the magnetic fields of stator and rotor does is zero under steady state operation?
What is use of starter and choke in tube light
what is the difference between switchgear and circuit breakers and is there any difference between outdoor and indoor switchgear and circuit breakers , and how would you differentiate between switch yard and substation and grid station . thanks
Is there any abbrevation for STUB in Stub bus protection
Why there are some equipment(i.e:TV) that using 2-pin plug instead of three? What happen if there is current leakage? Are we going to get electric shock??
Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend
. What is Electrical Life & Mechanical Life of Circuit Breaker? 2. What is Electrial Life & Mechanical Life of Magnetic Contactor? 3. What is RCD, RCCB & RCBO? 4. What is the Between defferance of RCD, RCCB & RCBO?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
from generating station If 400v LT line length is 1000m how much voltage is drop and how do i calculate it? which cable will be use for this line?
IN induction motor pf is increased using capacitors.what will be the effect on motor and system when very large capacitor is accidently installed and pf goes leading.
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
brief notes on ammeters
what is the effect of earth on capacitance in 3-phase and 1- phase transmission line?
How i can calculate current of cable according to ares?