what is the diffrence between mmwc and kg/cm2 for pressure
measurment when we are using mmwc and when kg/cm2 and why?????
?? what is the reason

Answer Posted / dilip

N/m2 is SI Unit and Kg(f)/cm2 is MKS Unit.

1 Kg/cm2 is 1.033 bar or 1.033x10^5 N/m2
10000 mmwc= 1 kg/cm2

Is This Answer Correct ?    105 Yes 16 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the use of double seated valve?

838


what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration

1668


what is the calibration procedure for magnetic flow meter @ onsite

1295


Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?

2026


I want to buy a seal kit of a pneumatic power cylinder.But I don't know it's specification.So please help me to know its specification.

1589






how to check earthing,what is minum ohms for proper earthing

1600


Isometric drawings are generated during _________________ phase of a project

1717


1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling

2060


how to turbine speed measurement?

1235


What do you know about gail?

2151


what is the difference between magnetic flow meter and mass flowmeter

996


Explain an adaptive / self-tuning controller’s major draw card.

1954


need instrumentation job completed 1 year trainee ship in mnc pesticide company. now in search of job

1570


the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove

1249


where uses EXe /EXd/Exo/Exn/Exp/Exq/EXia

9484