how to derive kg/cm2 to mmwc? complete derivation.
Answer Posted / gopalakrishnan
1 bar = 10000mmh2o
and 1 bar = 1000mmh2o is wrong
| Is This Answer Correct ? | 14 Yes | 16 No |
Post New Answer View All Answers
What is the diffrence between digital signal processing and discrete signal processing?
How do you identify an orifice in the pipeline?
what is a vortex flow meter,mass flow meter and electromagnetic flow meter.particular use of this.means in which condition particular meter is used.
why we are using drum level control valve air to close?
Somebody can explain me about >Critical Loops, calibrations, ESD critical Loop checks, Logic Diagram / Cause & Effect checks for ESD loops,
Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.
what is intrinscily safe system and where we use?
What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?
How can you add value to this Industry if offered the job?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
What is the difference between working pressure and calibration pressure of a control valve
Why we are using reverse action in displacer types level transmitters on some Vessels?
send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com
What is instrumentation measurement?
how many type conductivity sensor ?