Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how u meassure room temp?is it possible 2 meassure room
temp by rtd or thermocouple?between rtd n thrmocouple which
is more regard?3 meassure diff. between rtd n thermocouple?

Answer Posted / mahender mohal

Noramaly room temp. is msrd by thermometers. yes,from RTD
we can also measures room temp. if all other perameters are
neglected but not by thermocouple because of two juctions.
Diff:- 1)rtd is low range temp.sensorbut thermocouple is
for high range temp.
2)rtd measures temp.with change in resistance, thermocouple
measures temp.with reference of cold junction, its output
in mV.
3)rtd have large bulb size than thermocouple.
4)rtd have single metal while themocouple have two
dissimiler metal wires....etc.

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is instrument philosophy

2332


1.what is the power consumption of three element drum level control in sugar industries? 2.how to reduce that?

1689


How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer

2839


what is sil (safety integrity level

2791


1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?

2273


hi my name is rakesh patel i just complited my be in instrumentation & control now i am going to working as a validation engineer in a poject department so what is a scope in a future as a validation engginer ? what line is good for me can any bady give me complete solution please? your regard rakesh patel

2016


I am manjunath having exp in maintenance of chemical plants,know i want to do a design course INTOOLS,after doing design course can we get jobs in design field.sinve i dont have design exp..

1806


I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1949


Why do we have earthing cable in branch cable and shield in the same cable?

2656


what is difference between HOT permit and cold permit

2288


Name different types of bourdon tubes.

1201


WHAT IS THE DIFF. BETWEEN SKIN TEMPERATURE AND PASSES TEMPERATURE..?

2584


field bus transmitter calibration procedure tell me

1879


1.can you use SCADA instead of DCS,DCS instead SCADA 2.Difference between DCS and PLC,can their role be reversed i.e. role interchange 3.Difference between RTU and PLC

2651


NPN transistor, SCR, Zener diode, LED, Varactor diode, Vortex meter, RTD, Resistor, Crystal

2241