HOW DEFINE THE IP FOR ELECTRICAL EQUIPMENT AND WHAT IS THE
IP OF PANELS USING IN HAZARDOUS AREA ?
Answer Posted / arya anup
IP ratings means international protection rating based on
australian standards.1st digit stands for range of
protection against ingress of solids 2nd digit stands for
degree of protection aainst ingress of water.in hazardous
areas we can go for IP65/IP 66 as it means 6:complete
protection against dust 5: protection against low jets/6:
protection against heavy jets.
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
Help need in transformer !? Hello Friends The parameters of 2300/230 v 50hz t/f is R1=0.286 ohm R`2=0.319 ohm Rc=240 ohm X1=0.73 ohm X`2=0.73 ohm Xm=49.2 ohm Secondary Load impedance ZL=0.387+J0.29 solve the exact equivalent circuit with normal voltage across primery.. I know every thing but i cant find CURRENT I1=? and I`2=? Please help me give solution or only Formula please please...
can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?
what happen when power factor of 2 parallely operated transformer become equle?
How to calculate cable size in HT AND LT
How does "OUT OF STEP" relay ,for Synchronous motor protection, work?
could an induction motor be used for regenerative braking in electric-train control? in this type of application would some scheme have to be devised to obtain low synchronous speeds while braking? would induction-motor drive, therefore, be suitable for passenger service?
What is an alternator impedance value?
Why use in ht motore
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?
What is the effect of pi controller on the system performance?
what r PID controllers?why they r used?what is there purpose?plz Explain in detail
Actuality I have at home electrical panel with 220v 50hz, and I want to converter from there to 110v 60hz, to wiring on the half of my house. Also I like to keep another half of my house with the original 220v 50hz. What is the best and safety way to do?
If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.
what is different between phase and netural