Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how u meassure room temp?is it possible 2 meassure room
temp by rtd or thermocouple?between rtd n thrmocouple which
is more regard?3 meassure diff. between rtd n thermocouple?

Answer Posted / ramraj beda

rtd is low range temp.sensor(0-300) but thermocouple is for high range temp.(0-1400)
rtd measures temp.with change in resistance, thermocouple measures temp.with reference of cold junction, its output in mV.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

2221


Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd

2119


Using your own examples solve a problem involving normal table. (experimental method and analysis)

1170


how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744

2399


Is it ok, to use non-contact type Radar type LT, on a tank that is half circular from the bottom side? If yes the, isn't the waves gonna bent in other directions? 

2188


how to work static pressure sensore how to work dpt

1879


how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr

7924


Describe the function of Accumulator into the Pump

1937


Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .

2502


Why ac supply load cell is used? Can we use the dc supply load cell?

1070


send me last 5 years questions asked in rrb chennai, for section engineer

2109


How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer

2789


When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.

1824


For what reason would you possibly be compelled to make use of a Smith Predictor. Explain the idea behind the operation of this device.

1935


what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d

5407