Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how u calculate ups battery backup

Answer Posted / sathishkumar

battery backup calculations
Assumption battery bank cumulative voltage is equal to load
voltage
Q=1.25*total load current/i.e 0.8)

where the q=total capacity of the Battery Bank in Amp.hour.
and 0.8 is Battery efficiency coefficient for Lead Acid
batteries.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

given data are load current & power factor cable core size? plz any one update the calculation formula

1896


If one tertiary phase i.e. R,Y or B is earthed of a loaded type tertiary delta connected (Without load)of a power auto transformer, what is its advantage/disadvantage?

2085


what is the role and fuction of automatic transfer switch in rotary ups

1950


What is difference and reason b/w -48V BTS system and 24 V BTS system. Plzzzzzzzzz tel me.

2224


In Indian Household, generally we receive 220V AC single phase supply. But AC has 2 phases, +ve & -ve. So in +ve half cycle current is flowing...so what happens in the -ve half cycle?? Please illustrate.

2031


What is kirchoff ’s current law (kcl)?

1096


How to assume answer to electrical questions

1533


For RCD (Residual current device) Icu is defined. How i can find Ics for them?

2066


could an induction motor be used for regenerative braking in electric-train control? in this type of application would some scheme have to be devised to obtain low synchronous speeds while braking? would induction-motor drive, therefore, be suitable for passenger service?

2038


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1946


how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)

2369


working principles of cf lamp,incandescentlamp and f lamp?

2254


How much load can take a 16 mm aluminum cable 3 phase

1750


What is bode plot?

1246


EXPLAIN WHY THE SURGE CURRENT RATING OF AN MCCB OR CIRCUIT BREAKER DECREASES WITH INCREASE IN THE RATING OF MCCB OR CIRCUIT BREAKER.

2031