Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between c-8 and c-18 column

Answer Posted / kumar nagendra karapala

C-8 means having 8 carbons and C-18 (ODS) means having 18
carbons both are attached to silicaon groups to from
stationary phases for Chromatography.

Is This Answer Correct ?    13 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4025


acceptance criteria for lod & loq by standard deviation of response and slope??

2547


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1562


why require to do water content for drug product?

793


How to set analyticl specification for combination products?

695


what is mean by dissolution biowaiver study?

870


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

787


what is mean by dissolution hydrodynamics?

787


How we choose the mobile phase for method development.?

1177


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2134


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

9724


before starting analytical method valodation what you checking? and how giving preference to start validation?

759


how you start RS method development when for new product?

678


how you fix the limits of impurities?

802


i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me

2687