Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what's float charger and boost charger? why it's used?

Answer Posted / anil vasu

Float voltage is the voltage applying to the cells to prevent self discharge. boost voltage is the voltage applying to the cells for charging after a discharge.

Is This Answer Correct ?    45 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

when we have to use UPF wattmeter and LPF wattmeter? what is the difference between UPF and LPF wattmeter in terms of construction?

2488


what is the standard values(Megger test) of resistances between L&N,L&E and N&E for a system on IEE regulations?

2258


Is potential difference materials property ..? if yes tnen how.. explain brifly.

2044


What is the power factor of an alternator at no load?

1327


what is p.s impedance measurement test in earthing transformer?

2401


why are u join ntpc

2148


How to design a Unit auxiliary transformer for a power house having a unit of 65 MW and Generating voltage of 11 KV and Secondary voltage of 433V

2128


What it the purpose of parallel phasing transfomers??

1982


Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?

1936


Explain Circuit Breaker Trip Characteristics in detail.

2130


im working in one private compeny in gujarat. i was complet diploma electric in 2010 from gujarat technical board. now i want electric supervisor licence in gujarat but i dont't know when i apply? plz give me address of the licence dippartment office in gujarat. gandhinagar

1854


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1942


Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2212


how to control dc motor?

1906


what is the diference between the 4pole & 6pole DC Motors & what is advantage 6pole over the 4pole ?

1998