What is the acessaries distribution transformer ?
Answer Posted / bhawana maurya
Main Parts-
Core & Frame
Windings
Tank & Cover
Base Channel
LV & HV Bushings
Tap Changer Switch
Earth Terminals
Rating Plate
Jacking Plate
Auxiliary Parts-
Radiators
Conservator
Vent Pipe with diaphram
Breather
Buchholz Relay or Gas Formation relay
Arcing Horn
Drain Valve
Indicating Apparatus
Oil Gauge
Temperature Indicator
Pressure Gauge
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Why does the speed regulating system adopting I controller have no steady-state error? In this single closed-loop speed regulating system, when the input of the I controller Un=0, what is the output voltage of the regulator? What factors do the output voltage depend on?
With a phasor diagram show the effect of increasing the field current of a generator supplying a constant real power and connected to a grid system.
What is the effect of positive feedback on the stability of the systems?
What are the advantage of free wheeling diode in a full wave rectifier?
whit is 33kv power 300*300 cable full current with formula
how the characterstics of control valve being done
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
I want to design a heating coil of 80/20 nicrome for 3.5KW please give me the calculations choosing for physical dimensions assume coil voltage will be 110V AC assume necessary conditions
why 5kW motor becomes unbalance if its relay trip 1st time and its set value is 7.0 A
what is the easiest method of short circuit current calculation ? pls. derive with a mathematical example in real life application.
is it necessary to earth the rmu before cutting off the transformer winding?if yes why?
How to calculate no of Lighning arrestors are required for protecting 50mX 50m*20m cubical building and locations of LA?
static chagre
if voltage bt phase & nutral is 38v in a panel board . whats the root cause.
What is difference is of VSD,VFD,VSDS, are they the same as the direct current to control dc using above mention