Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the significance of KV & MVA rating of the
transformer and how they are related.

Answer Posted / deepu

Simply kv is used for
distribution and mva
for transmission
purpose

Is This Answer Correct ?    14 Yes 31 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why the field rheostat is adjusted such that the voltmeter reads 380V

2233


What are the advantages of speed control using thyristor?

1069


What the difference between ac and dc inductor an capacitor

2340


A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

2516


If SFU is Switch Fuse Unit, What is the expansion for FSHF in Electrical Engineering?

2536


How to decide DO set rating of Transformer?

1609


WHY CBCT USE ONLY IN Y PHASE NOT OTHER PHASES

2044


What is the rate of WCT on the Electrical Contracts comprising of DG Sets and Civil Works in Delhi ?

2137


what is meant by the phrase 'static load' in case of shorting in a generator excitation system?

2099


I am going to appear RRB Sr. Section Engineer Exam, Electrical. Can you send me previous year questions of RRB Electrical engineer. specially Section Engineer questions. my email id is likerahulworld@gmail.com

1759


We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?

2042


we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.

6946


ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]

2285


why impudance relay used for medium transmission power system? why not others?

1406


What is the selection process of breakers. Can any one please give a formulation on same?