what is the basic principal of vertax flow meter
Answer Posted / abhishek k sharma
vortex is natural phenomena occurring when liquid flow
around a bluff object.
For e.g when we throw the stone in water it generates vortex
in round circle.
same happens when a object is placed in between running liquid.
In vortex flow meter same is used and the frequency of
vortex generated is directly proportional to velocity of
liquid flowin.
Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
How the warning lamp of a charging-system is activated ?
Why are the uses 24vdc in industries
Describe the function of Accumulator into the Pump
applications of plc in printing and packaging?
What is three element in drum level?
any one can send me instrumentation previous interview papers? I prepare for MNC Company Interviews? my mail id- Rakesh.Golla@dodsaldxb.ae , and another mail rakesh.gvk@gmail.com
What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch
how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr
In apron feeder how TPH is calculated?
TEMPERATURE VARIATION FOR FREQUENTLY.
What is critcal speed. what is resonant frequency. why we want to cross crtcal speed on higher RPM (early).
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
Sir , i have completed my M.Sc In Instrumentation and presently working in Maintenance department 3 yrs Exp , is there is any possible for work in offshore ..
what is the responsibility of an instrument commissioning supervisor