The temperature rise in the sys, which leads to …..
a) Increases stress& length b) increases stress but
decreases length c) Decreases stress & increase length
d) decrease stress & length

Answer Posted / sundar

option: b)

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the importance of counter based plan & how is it scheduled?

1565


A cable with concentric PE conductor must be used with frequency converter circuits what does its means.?

1126


1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done

1486


What is the use of Surge Capacitor in LAVT?

12916


What difference between ref protection and differential protection ?

1341






hi if anybody got model questions for cpcl Grade'A' electrical engineer position.send it to my mail please krishkumar22@gmail.com

1483


Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.

1973


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

1748


Explain the working of variable frequency transformer?

660


what can be the causes of capacitor start motor having a higher current that its actual

1514


Explain about technical and non technical losses in distribution system?

627


If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.

1475


HOW DO YOU CAN CHECK A 15KV DIODE, WHETHER IT IS OK OR NOT?

1502


How can I model an open-delta ground transformer for a network supplied by 4 unit GTG and power transformer in ETAP?

13295


what is the necessity of under ground cables ??

1634